Modeli
Heatcharge. Energy Charge System.
Energy class A+++ and offers maximum comfort and energy savings. This powerful air heat pump is designed for commercial and residential climate that places extremely high demands on the heating system.
Bringing nature’s balance indoors
Discover the latest generation of air conditioning system
Great savings and improved wellness
Our air conditioners produce the highest comfort with a very small energy cost, creating a clean air, free of viruses, bacteria, pollen and odours.
A range of products designed for you
From the smaller 1X1 to the more complete 5x1 solutions, it doesn’t matter which your need is. Panasonic can offers you the best solution to get the best clima in your home.
A comfortable home all year round
Our air conditioners give you the most comfortable temperature all year long, heating in winter, cooling in summer and cleaning the ambience during the whole year.
Great savings and improved wellness
Our air conditioners produce the highest comfort with a very small energy cost, creating a clean air, free of viruses, bacteria, pollen and odours.
A range of products designed for you
From the smaller 1X1 to the more complete 5x1 solutions, it doesn’t matter which your need is. Panasonic can offers you the best solution to get the best clima in your home.
A comfortable home all year round
Our air conditioners give you the most comfortable temperature all year long, heating in winter, cooling in summer and cleaning the ambience during the whole year.
The air conditioning connects with the future
Specifikacije
Heatcharge VZ Inverter+ • R32 | JEDNOFAZNO | |||
---|---|---|---|---|
2.5 kW | 3.5 kW | |||
Kit | KIT-VZ9-SKE | KIT-VZ12-SKE | ||
Cooling capacity (Nominal) | kW | 2,50 | 3,50 | |
Cooling capacity (Min) | kW | 0,60 | 0,60 | |
Cooling capacity (Max) | kW | 3,00 | 4,00 | |
SEER (2) | 10,50 A+++ | 10,00 A+++ | ||
Pdesign (cooling) | kW | 2,50 | 3,50 | |
Input power cooling (Nominal) | kW | 0,43 | 0,80 | |
Input power cooling (Min) | kW | 0,14 | 0,14 | |
Input power cooling (Max) | kW | 0,61 | 0,98 | |
Annual energy consumption cooling (3) | kWh/a | 83,00 | 122,00 | |
Heating capacity (Nominal) | kW | 3,60 | 4,20 | |
Heating capacity (Min) | kW | 0,60 | 0,60 | |
Heating capacity (Max) | kW | 7,80 | 9,20 | |
Heating capacity at -7°C | kW | 5,00 | 5,60 | |
COP (Nominal) (1) | W/W | 5,63 | 5,04 | |
SCOP (2) | 6,20 A+++ | 5,90 A+++ | ||
Pdesign at -10°C | kW | 3,60 | 4,20 | |
Input power heating (Nominal) | kW | 0,64 | 0,83 | |
Input power heating (Min) | kW | 0,14 | 0,14 | |
Input power heating (Max) | kW | 2,72 | 3,16 | |
Annual energy consumption heating (3) | kWh/a | 812 | 995 | |
Indoor unit | CS-VZ9SKE | CS-VZ12SKE | ||
Indoor power source | V | 230 | 230 | |
Indoor recommended fuse | A | 16 | 16 | |
Indoor connection indoor / outdoor | mm² | 4 x 1,5 | 4 x 1,5 | |
Indoor air flow (Cool) | m³/min | 12,5 | 12,9 | |
Indoor air flow (Heat) | m³/min | 15,5 | 15,9 | |
Indoor sound pressure (Cool -Hi) (4) | dB(A) | 44 | 45 | |
Indoor sound pressure (Cool -Lo) (4) | dB(A) | 27 | 33 | |
Indoor sound pressure (Cool -Q-Lo) (4) | dB(A) | 18 | 18 | |
Indoor sound pressure (Heat -Hi) (4) | dB(A) | 44 | 45 | |
Indoor sound pressure (Heat -Lo) (4) | dB(A) | 26 | 29 | |
Indoor sound pressure (Heat -Q-Lo) (4) | dB(A) | 18 | 18 | |
Indoor dimension (Height) | mm | 295 | 295 | |
Indoor dimension (Width) | mm | 798 | 798 | |
Indoor dimension (Depth) | mm | 375 | 375 | |
Indoor net weight | kg | 14,5 | 14,5 | |
Outdoor unit | CU-VZ9SKE | CU-VZ12SKE | ||
Outdoor air flow (Cool) | m³/min | 33,1 | 35,4 | |
Outdoor air flow (Heat) | m³/min | 33,1 | 33,9 | |
Outdoor sound pressure (Cool -Hi) (4) | dB(A) | 49 | 50 | |
Outdoor sound pressure (Heat -Hi) (4) | dB(A) | 49 | 50 | |
Outdoor dimension (Height) (5) | mm | 630 | 630 | |
Outdoor dimension (Width) (5) | mm | 799 | 799 | |
Outdoor dimension (Depth) (5) | mm | 299 | 299 | |
Outdoor net weight | kg | 39,5 | 39,5 | |
Pipe diameter (Liquid) | Inch (mm) | 1/4 (6,35) | 1/4 (6,35) | |
Pipe diameter (Gas) | Inch (mm) | 3/8 (9,52) | 3/8 (9,52) | |
Pipe length range | m | 3 ~ 15 | 3 ~ 15 | |
Elevation difference (in/out) (6) | m | 12 | 12 | |
Pipe length for additional gas | m | 7,5 | 7,5 | |
Additional gas amount | g/m | 20 | 20 | |
Refrigerant (R32) / CO2 Eq. | kg / T | 1,05 / 0,70875 | 1,10 / 0,7425 | |
Operating range (Cool - Min) | °C | -10 | -10 | |
Operating range (Cool - Max) | °C | +43 | +43 | |
Operating range (Heat - Min) | °C | -30 | -30 | |
Operating range (Heat - Max) | °C | +24 | +24 | |
Lowest outdoor temperature tested by 3rd party laboratory (7) | °C | -35 | -35 |
(1) Energy Label Scale from A+++ to D.
(2) EER and COP calculation is based in accordance to EN14511.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) The sound pressure of the indoor unit shows the value measured of a position 1 m in front of the main body and 0,8 m below the unit. For outdoor unit 1 m in front and 1 m in rear side of main body. The sound pressure is measured in accordance with JIS C 9612. Q-Lo: Quiet mode. Lo: The lowest set fan speed.
(5) Add 70 mm for piping port.
(6) When installing the outdoor unit at a higher position than the indoor unit.
(7) Tested by 3rd party laboratory, SP, according to EN14511:2013 and SP Method 1721, this temperature is not guaranteed by Factory.