Aquarea High Performance All in One Compact J Generation 1 Phase · R32

Aquarea All in One Compact unit is the ultimate space-saving solution

Aquarea warms your home effectively and efficiently, even with extreme outdoor temperatures. Aquarea can also cool space in summer and bring hot water all year round.

Aquarea High Performance is the range for new installations and low consumption homes. Outstanding efficiency and energy savings with minimised CO2 emissions and minimum space.

The Aquarea All in One belongs to the new generation of Panasonic heat pumps for heating, cooling and providing domestic hot water in the home. Improved square design with white goods finish.

Its 598 x 600 mm footprint, standard size of other big appliances, reduces the space required for the installation.

The newest of Aquarea

Specifikacije

See all
Aquarea High Performance All in One Compact J Generation 1 Phase · R32 Jednofazno (napajanje unutarnje jedinice)
3 kW 5 kW 7 kW 9 kW
Kit KIT-ADC03JE5C KIT-ADC05JE5C KIT-ADC07JE5C KIT-ADC09JE5C-1
Heating capacity (A +7°C, W 35°C) kW 3,20 5,00 7,00 9,00
COP (A +7°C, W 35°C) 5,33 5,00 4,76 4,48
Heating capacity (A +7°C, W 55°C) kW 3,20 5,00 7,00 8,95
COP (A +7°C, W 55°C) 2,81 2,72 2,82 2,78
Heating capacity (A +2°C, W 35°C) kW 3,20 4,20 6,85 7,00
COP (A +2°C, W 35°C) 3,64 3,18 3,41 3,40
Heating capacity (A +2°C, W 55°C) kW 3,20 4,10 6,20 6,30
COP (A +2°C, W 55°C) 2,19 1,99 2,21 2,16
Heating capacity (A -7°C, W 35°C) kW 3,30 4,20 5,60 6,12
COP (A -7°C, W 35°C) 2,80 2,59 2,87 2,78
Heating capacity (A -7°C, W 55°C) kW 3,20 3,55 5,25 5,90
COP (A -7°C, W 55°C) 1,79 1,71 1,94 1,93
Cooling capacity (A 35°C, W 7°C) kW 3,20 4,50 6,70 8,20
EER (A 35°C, W 7°C) 3,52 3,00 3,03 2,72
Cooling capacity (A 35°C, W 18°C) kW 3,20 4,80 6,70 9,00
EER (A 35°C, W 18°C) 4,85 4,29 4,72 4,18
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 200 / 136 200 / 136 193 / 130 193 / 130
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 5,07 / 3,47 5,07 / 3,47 4,90 / 3,32 4,90 / 3,32
Heating average climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A++ A+++ / A++ A+++ / A++ A+++ / A++
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 245 / 165 245 / 165 227 / 160 227 / 160
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 6,20 / 4,20  6,20 / 4,20  5,75 / 4,07 5,75 / 4,07
Heating warm climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A+++ A+++ / A+++ A+++ / A+++ A+++ / A+++
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 157 / 110 157 / 110 164 / 116 164 / 116
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,00 / 2,83 4,00 / 2,83 4,18 / 2,98 4,18 / 2,98
Heating cold climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A++ / A+ A++ / A+ A++ / A+ A++ / A+
Indoor unit WH-ADC0309J3E5C WH-ADC0309J3E5C WH-ADC0309J3E5C WH-ADC0309J3E5C
Indoor sound pressure (Heat) dB(A) 28 28 28 28
Indoor sound pressure (Cool) dB(A) 28 28 28 28
Indoor dimension (Height) mm 1650 1650 1650 1650
Indoor dimension (Width) mm 598 598 598 598
Indoor dimension (Depth) mm 600 600 600 600
Indoor net weight kg
Water pipe connector Inch R 1¼ R 1¼ R 1¼ R 1¼
A class pump (Number of speeds) Variable Speed Variable Speed Variable Speed Variable Speed
A class pump (Input power Min) W 30 30 30 30
A class pump (Input power Max) W 120 120 120 120
Heating water flow (∆T=5 K. 35°C) L/min 9,20 14,30 20,10 25,80
Capacity of integrated electric heater kW 3,00 3,00 3,00 3,00
Indoor recommended fuse A 16 / 16 16 / 16 25 / 16 25 / 16
Recommended cable size, supply 1 mm² 3 x 1,5 3 x 1,5 3 x 2,5 3 x 2,5
Recommended cable size, supply 2 mm² 3 x 1,5 3 x 1,5 3 x 1,5 3 x 1,5
Water volume L 185 185 185 185
Maximum water temperature °C 65 65 65 65
Material inside tank Stainless steel Stainless steel Stainless steel Stainless steel
Tapping profile according EN16147 L L L L
DHW tank ERP average climate efficiency rating (2) A+ to F A+ A+ A+ A+
DHW tank ERP warm climate efficiency rating (2) A+ to F A+ A+ A+ A+
DHW tank ERP cold climate efficiency rating (2) A+ to F A A A A
DHW tank ERP average climate η ηwh % 132 132 120 120
DHW tank ERP average climate SCOP 3,30 3,30 3,00 3,00
DHW tank ERP warm climate η ηwh % 155 155 140 140
DHW tank ERP warm climate SCOP 3,88 3,88 3,50 3,50
DHW tank ERP cold climate η ηwh % 99 99 99 99
DHW tank ERP cold climate SCOP 2,48 2,48 2,47 2,47
Outdoor unit WH-UD03JE5 WH-UD05JE5 WH-UD07JE5 WH-UD09JE5-1
Outdoor sound power part load (Heat) (3) dB(A) 55 55 59 59
Outdoor sound power full load (Heat) dB(A) 60 64 68 69
Outdoor sound power full load (Cool) dB(A) 61 64 67 69
Outdoor dimension (Height) mm 622 622 795 795
Outdoor dimension (Width) mm 824 824 875 875
Outdoor dimension (Depth) mm 298 298 320 320
Outdoor net weight kg 37 37 61 61
Refrigerant (R32) / CO2 Eq. kg / T 0,9 / 0,608 0,9 / 0,608 1,27 / 0,857 1,27 / 0,857
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35)
Pipe diameter (Gas) Inch (mm) 1/2 (12,70) 1/2 (12,70) 5/8 (15,88) 5/8 (15,88)
Pipe length range m 3 ~ 25 3 ~ 25 3 ~ 50 3 ~ 50
Elevation difference (in/out) m 20 20 30 30
Pipe length for additional gas m 10 10 10 10
Additional gas amount g/m 20 20 25 25
Operation range (Outdoor ambient) °C -20 ~ +35 -20 ~ +35 -20 ~ +35 -20 ~ +35
Water outlet (Heat) °C 20 ~ 60 20 ~ 60 20 ~ 60 20 ~ 60
Water outlet (Cool) °C 5 ~ 20 5 ~ 20 5 ~ 20 5 ~ 20

(1) Scale from A+++ to D.
(2) Scale from A+ to F.
(3) Sound power in accordance to 8112013,81312013 and EN12102-1:2017 at +7°C.
EER and COP calculation is based in accordance to EN14511.
This product is designed to comply with the European Water Quality Directive 98/83/EC amended by 2015/1787/EU. The lifespan of the product is not guaranteed in the case of the use of groundwater, such as spring water or well water, the use of tap water when salt or other impurities are contained, nor in areas of acidic water quality. Maintenance and warranty costs related to these cases are the customer’s responsibility.

Complementary products