Aquarea HT Mono-bloc G Generation 1 Phase. Heating Only • R407C

Previous capacity Next capacity

Aquarea, an innovative new low-energy system based on Air to Water heat pump technology


Aquarea warms your home effectively and efficiently, even with extreme outdoor temperatures. Aquarea can also cool space in summer and bring hot water all year round.
Aquarea HT can produce a flow temperature of 65°C making it the ideal high efficiency replacement for oil/gas boilers connected to high temperature radiators.
The Mono‑Bloc system: This only has an outdoor unit. The installation doesn’t require a refrigerated connection and is only connected to the heating and/or hot water.

A heat pump turns heat energy outside into warmth inside

Specifikacije

See all
Aquarea HT Mono-bloc G Generation 1 Phase. Heating Only • R407C
9 kW
Outdoor unit WH-MHF09G3E5
Heating capacity (A +7°C, W 35°C) kW 9,00
COP (A +7°C, W 35°C) 4,64
Heating capacity (A +7°C, W 55°C) kW 9,00
COP (A +7°C, W 55°C) 2,48
Heating capacity (A +2°C, W 35°C) kW 9,00
COP (A +2°C, W 35°C) 3,45
Heating capacity (A +2°C, W 55°C) kW 9,00
COP (A +2°C, W 55°C) 2,06
Heating capacity (A -7°C, W 35°C) kW 9,00
COP (A -7°C, W 35°C) 2,74
Heating capacity (A -7°C, W 55°C) kW 9,00
COP (A -7°C, W 55°C) 1,79
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 153 / 125
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 3,90 / 3,20
Heating average climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A++ / A++
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 191 / 156
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,85 / 3,98
Heating warm climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A+++
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 137 / 116
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 3,50 / 2,98
Heating cold climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+ / A+
Outdoor sound power full load (Heat) dB(A) 68
Outdoor dimension (Height) mm 1410
Outdoor dimension (Width) mm 1283
Outdoor dimension (Depth) mm 320
Outdoor net weight kg 151
Refrigerant (R32) / CO2 Eq. (2) kg / T 1,92 / 3,406
Refrigerant (R407C) / CO2 Eq. (2) kg / T 1,92 / 3,406
Water pipe connector Inch R 1¼
Pump (Number of speeds) 7
Heating water flow (∆T=5 K. 35°C) L/min 25,80
Capacity of integrated electric heater kW 3,00
Input power (Heat) kW 1,94
Running and starting current (Heat) A 9,3
Current 1 A 28,5
Current 2 A 13
Indoor recommended fuse A 30 / 30
Recommended cable size, supply 1 mm² 3 x 4,0 or 6,0
Recommended cable size, supply 2 mm² 3 x 4,0
Operation range - outdoor temperature (Heat) °C -20 ~ +35
Water outlet (Heat) °C 25 ~ 65

(1) Sound power in accordance to 8112013,81312013 and EN12102-1:2017 at +7°C.
(2) WH-MHF models are hermetically sealed.
EER and COP calculation is based in accordance to EN14511.

Complementary products