Aquarea High Performance All in One J Generation 1 Phase • R32

Previous capacity Next capacity

Aquarea, an innovative new low-energy system based on Air to Water heat pump technology 


Aquarea warms your home effectively and efficiently, even with extreme outdoor temperatures. Aquarea can also cool space in summer and bring hot water all year round.

Aquarea High Performance is the range for new installations and low consumption homes. Outstanding efficiency and energy savings with minimised CO2 emissions and minimum space.

Aquarea All in One: This range intelligently integrates the best Hydrokit technology with a premium quality stainless steel tank, which is maintenance-free.

Aquarea, contributing to a decarbonised society

Specifikacije

See all
Aquarea High Performance All in One J Generation 1 Phase • R32
3 kW
Kit KIT-ADC03JE5
Heating capacity (A +7°C, W 35°C) kW 3,20
COP (A +7°C, W 35°C) 5,33
Heating capacity (A +7°C, W 55°C) kW 3,20
COP (A +7°C, W 55°C) 2,81
Heating capacity (A +2°C, W 35°C) kW 3,20
COP (A +2°C, W 35°C) 3,64
Heating capacity (A +2°C, W 55°C) kW 3,20
COP (A +2°C, W 55°C) 2,19
Heating capacity (A -7°C, W 35°C) kW 3,30
COP (A -7°C, W 35°C) 2,80
Heating capacity (A -7°C, W 55°C) kW 3,20
COP (A -7°C, W 55°C) 1,79
Cooling capacity (A 35°C, W 7°C) kW 3,20
EER (A 35°C, W 7°C) 3,52
Cooling capacity (A 35°C, W 18°C) kW 3,20
EER (A 35°C, W 18°C) 4,85
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 200 / 136
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 5,07 / 3,47
Heating average climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A++
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 245 / 165
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 6,20 / 4,20 
Heating warm climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A+++
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 157 / 110
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,00 / 2,83
Heating cold climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A++ / A+
Indoor unit WH-ADC0309J3E5
Indoor sound pressure (Heat) dB(A) 28
Indoor sound pressure (Cool) dB(A) 28
Indoor dimension (Height) mm 1800
Indoor dimension (Width) mm 598
Indoor dimension (Depth) mm 717
Indoor net weight kg 122
Water pipe connector Inch R 1¼
A class pump (Number of speeds) Variable Speed
A class pump (Input power Min) W 30
A class pump (Input power Max) W 120
Heating water flow (∆T=5 K. 35°C) L/min 9,20
Capacity of integrated electric heater kW 3,00
Indoor recommended fuse A 16 / 16
Recommended cable size, supply 1 mm² 3 x 1,5
Recommended cable size, supply 2 mm² 3 x 1,5
Water volume L 185
Maximum water temperature °C 65
Material inside tank Stainless steel
Tapping profile according EN16147 L
DHW tank ERP average climate efficiency rating (2) A+ to F A+
DHW tank ERP warm climate efficiency rating (2) A+ to F A+
DHW tank ERP cold climate efficiency rating (2) A+ to F A
DHW tank ERP average climate η ηwh % 132
DHW tank ERP average climate SCOP 3,30
DHW tank ERP warm climate η ηwh % 155
DHW tank ERP warm climate SCOP 3,88
DHW tank ERP cold climate η ηwh % 99
DHW tank ERP cold climate SCOP 2,48
Outdoor unit WH-UD03JE5
Outdoor sound power part load (Heat) (3) dB(A) 55
Outdoor sound power full load (Heat) dB(A) 60
Outdoor sound power full load (Cool) dB(A) 61
Outdoor dimension (Height) mm 622
Outdoor dimension (Width) mm 824
Outdoor dimension (Depth) mm 298
Outdoor net weight kg 37
Refrigerant (R32) / CO2 Eq. kg / T 0,9 / 0,608
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35)
Pipe diameter (Gas) Inch (mm) 1/2 (12,70)
Pipe length range m 3 ~ 25
Elevation difference (in/out) m 20
Pipe length for additional gas m 10
Additional gas amount g/m 20
Operation range (Outdoor ambient) °C -20 ~ +35
Water outlet (Heat) °C 20 ~ 60
Water outlet (Cool) °C 5 ~ 20

(1) Scale from A+++ to D.
(2) Scale from A+ to F.
(3) Sound power in accordance to 8112013,81312013 and EN12102-1:2017 at +7°C.
EER and COP calculation is based in accordance to EN14511.
This product is designed to comply with the European Water Quality Directive 98/83/EC amended by 2015/1787/EU. The lifespan of the product is not guaranteed in the case of the use of groundwater, such as spring water or well water, the use of tap water when salt or other impurities are contained, nor in areas of acidic water quality. Maintenance and warranty costs related to these cases are the customer’s responsibility.

Complementary products